BALCONY




   AUTOMATIC IRRIGATION FOR BALCONY


Many times ready set automatic irrigation containing and developers can create problem in your balcony. There are cases the programmer may not be the right for you. If you really want a proper watering system for potted plants you follow the instructions!


                                      How to construct
      Before manufacture automatic watering in our terrace leading role shunned
Most technicians are the static pressure tap is our hydraulic shocks generated causing stress on our solenoid. Terminology "static pressure" means water pressure   in the network when the tap is closed and hydraulic shocks raise extra pressure when the tap close abruptly. The intense high pressure in the water supply network is able to spoil or even break the mechanism of automatic   watering system (electro) with major economic consequences of missing holiday.
      The pressure    of the counting network ( click here ) with a 10 gauge Bar and wiring which a valve on one side and one on the other fittings.Through the fittings connect to our tap. When you
open it, the gauge will show us the static pressure. Abruptly by switching the valve of wiring, we see the ups and downs gauge pressure hydraulic shocks. The stress is particularly pronounced when   the fountain is near check valve or lack pressure vessel and the lack of gear when we have a high pressure grid.

GAUGE


                                   
     For professional manufacturing automatic watering is a big mistake to not have a flow meter for the study. The following flow meter consists from right to left, with a metal fitting (to connect easily to the thread of the tap taking measurements), a pressure gauge 160 psi (approximately on the 11thBar ) screwed onto a black plastic breast after a valve, after half some sensitive pressure gauge on the 2nd Bar on which benefits are listed in gallons per minute (1000litra per hour is about 4.5 gallons per minute) and finally a black plastic cap with a hole diameter on the 6th mm .    

Flow meter


  Regarding stylish programmers automatic watering battery porch, usually have a limit of six ATM (approximately on the 6th Bar ). There are more professional lagging usually looks resistant and on the 10thATM . These markings shall be written by developers in the instructions.If the static pressures or stresses exceed these limits must put our gear on tap (I have received personal case while static pressure was the 4th Bar , stress can exceed the 15th Bar !!! So do not be misled by the small static pressure). Unscrew the faucet and connect our ports the gear 
(metal pressure regulator). To have watertight wrapping the threaded Teflon. The wrapping is done clockwise, by about 20 cycles (depending on the thickness of the Teflon film and the thread). Careful not to make the mistake and screwed upside down! That is, the front and rear front rear. Not to be wrong note on the gear toxaki showing the flow of water. The gear has a screw which regulate static pressure in the limit we want. By controlling the pressure gauge will see the limit of pressure and we see that there are no more extra   stress over the limit!


METAL GEAR VRYSIS

      
     After the issue of the pressures we have the issue with the developer! In principle there is no commercially developer that does not have flaws!Everyone has flaws and their virtues. And as with all machinery, there is a small chance spoil us unexpectedly. This is our great anxiety when we leave for long holidays. A programmer can spoil by:
A)     excessive pressure and strain on the network (solution reducer or  market programmer with resistance to high pressure)
B) excessive cold thereby freezes the water inside and the breaks (solution protected sites or  unscrewing the tap or  drain water inside)    
PLASTIC GEAR VRYSIS
C) Outdoor humidity (solution protected sites rains or  buy waterproof programmer)    
D) batteries (take care of before we leave for long holidays have new batteries or market developer does not absorb quickly the batteries)   
E) electronic damage (to the solution we have tested several weeks before we left to make sure that it displays unexpected obstacles or  have supervised our porch some our knowledge or installation flowmeters close automatically after providing excessive amounts of water or  sensor placement flow in taps with sms programmer to automatically notify us via mobile phone for every time you blink the automatic watering)    

     Besides all these important say in the choice of the programmer uses and practicality! We do not buy programmer without knowing if we would serve the program. There are developers with predefined programs that do not meet our watering needs throughout the year. If for example the summertime watering pots I want two minutes per day   or spring 2 minutes every 3 days  and the programmer does not have this feature are not practical.
     
     Developer we can screw onto the faucet. If the faucet is not our protrudes   sufficiently from the wall and the programmer does not have room to screw, then unscrew the faucet and put our intermediate tap extension.
     Usually the fountain terrace want it for other purposes. Therefore we replace  the faucet with a single or double screw on the single metal (not plastic) component with 2 valves.


DOUBLE TAP




       After selecting the developer series has hose (tube). The rubber used is 16mm irrigation (ie the 16th mm outer diameter), the 6th enduranceATM from polyaithylenio.Ta colors we choose are black, white and brown. We study the route they will pass the hose. If the automaton is temporary so we pass in front of the pots to collect easily when we get back from vacation. If you want a permanent pass behind the pots not easily seen. We can if we want to stab you with distaffs 16mm cables. We prefer the nails used in distaffs   be short and carefully pinning the joints of the tiles or on  the window sill in concrete

ROKES


   We also support the   insignia on the railing of the balcony using cable ties

CABLE TIES

    Commercially available and special adhesive bases for bundles to walls through which passes bales and tie their tubes



                                                                             Sticker - BOLTED BASIS FOR TIES


                                      
Do not try to stick the tube directly on the wall with glue or silicone heated because the polyethylene did not catch adhesives and peel away.

      After series has the wiring of the tube. Note the following components :
PARTS DIAGRAMS

  1. Connector 16mm
  2. Angle 16mm male plug ½ inch (or 3/4 inch)
  3. Tee 16mm
  4. Angle 16mm
  5. 16mm binocular
  6. Link F6
  7. Angle F6
  8. Cap
  9. Tee F6
  10. Taking
  11. Emitter adjustable 0-60litra per hour
  12. Bracket emitter
  13. Sgrompia
  14. breast ½ inch (or 3/4 inch or 1 inch)
  15. Tee arsenic    ½ inch (or 3/4 inch or 1 inch)
  16. Angle male   ½ inch (or 3/4 inch or 1 inch)
  17. Breast reducers ½ - ¾ inch (or ¾ -1 inch)
  18. Coupler ½ inch (or 3/4 inch or 1 inch)
  19. Tee female ½ inch (or 3/4 inch or 1 inch)
  20. Angle feminine ½ inch (or 3/4 inch or 1 inch)
  21. Racor thiliko-male ¾ inch
  22. Link lock 16mm
  23. Tee lock 16mm
  24. Angle lock 16mm


   Materials Wiring Connector F16 serve to connect two 16mm tires. The material of the plug must be from acetal rather than polyethylene because it will not be safe at high pressures and can be disconnected. Acetal is harder plastic material and spikes gripped satisfactorily polyaithyleneiou hose and hold it firmly. To make sure that the material is acetal rather polyaithyleneio we can put it into water. Polyethylene floats while the acetal as heavier material sinking!
   Materials wiring Lock is made ​​of polyethylene and hold tight and lockable rubber due to the external sphincter which is bolted to them. If you remove the clamps and the rest of the extra plastic Lock, be converted into breasts ¾, ¾ males tees    and masculine angles ¾   respectively.Besides connecting pipes   serve in connection with pipe threads.
  
Tee LOCK
With the help of Lock join the developer with the hose.
For example, if   the output of the programmer are male threaded ¾ inch, then screw it in a sleeve ¾, then   into the grommet screw thread of Lockand end at Lock adjust the tire.
      
       Do not forget the threads to wrap teflon to have tightness. The clamp Lock does not need Teflon.



TEFLON
      Following post-route the hose if we want to make some points vertical corners we can cut at these points and to reconnect with corners plug 16mm acetal. When connecting the hose pushing forcefully shaking up and down (without rotating it) and just get sufficiently deep to rotate side to side to agkylothei well.
     Close to pierce the rubber planters with sgrompia or other pointed object (eg a nail) and place a download link or F6. In this place a tube F6 (called macaroni and F6) and cut to the desired length to reach up the pot. On the edge of an emitter place and support the soil with plastic holder emitter characteristic of photography. At the end of the hose, place a folded binocular keeps the hose to not have leakage
   Finally we test and adjust their Stalachto provide ideal amount of water according to the needs of each plant. If high pressure shut gently tap to not have leaks from the downloads.



http://www.texnagron.gr/ materials Automatic Watering
They will address :
For more details
Tsimpli Theodore T. Agronomist
6972691861


No comments:

Post a Comment